Here at Internet of NSN, our team supplies and delivers NSN parts such as 962044 and Transformer Power from Trak Microwave Corp as well as other certified producers. Our stock of items includes more than six billion new, old and out of date airline parts, along with parts for the industrial and electronics industry. One of the leading independent suppliers with a strict No China Sourcing vow, Internet of NSN has been earning its reputation as a safe and reliable parts distributor. We value our relationship with our clients which is why we have gone above and beyond in earning our ISO 9001:2015 and AS9120B certifications.
We have many NSN part numbers in our stock, including 5950002712187 and many others. If you are in a quick need to source, we are your best bet on getting that part 962044 delivered to you quickly! Simply search our parts directory for the NSN code that you need (you may also search by CAGE code or part number), and once you are able to locate the part, send in that Instant RFQ. An account manager will reach out to you in as little as fifteen minutes to provide you with a same day quote and let you know how quickly we can supply your item(s) for you. Whatever you need, be it electronic semiconductors, batteries, circuit breakers, motherboards, circuit sheets, or others, our team at Internet For NSN has the part(s) that you need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-271-2187 Item Description: Transformer Power | 5950 | 002712187 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
962044 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.290 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.290 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.970 INCHES MINIMUM AND 3.970 INCHES MINIMUM AND 4.030 INCHES MAXIMUM4.030 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.720 INCHES MINIMUM AND 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM2.780 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.870 INCHES MINIMUM AND 3.870 INCHES MINIMUM AND 3.930 INCHES MAXIMUM3.930 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY176.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY32.70 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.70 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY176.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 32.70 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY25.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | SECONDARY CURRENT HAS BEEN RECTIFIED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |