Here at Internet of NSN, our team supplies and delivers NSN parts such as 7274-62-3 and Circuit Breaker from Sensata Technologies Inc as well as other certified producers. Our stock of items includes more than six billion new, old and out of date airline parts, along with parts for the industrial and electronics industry. One of the leading independent suppliers with a strict No China Sourcing vow, Internet of NSN has been earning its reputation as a safe and reliable parts distributor. We value our relationship with our clients which is why we have gone above and beyond in earning our ISO 9001:2015 and AS9120B certifications.
We have many NSN part numbers in our stock, including 5925014178690 and many others. If you are in a quick need to source, we are your best bet on getting that part 7274-62-3 delivered to you quickly! Simply search our parts directory for the NSN code that you need (you may also search by CAGE code or part number), and once you are able to locate the part, send in that Instant RFQ. An account manager will reach out to you in as little as fifteen minutes to provide you with a same day quote and let you know how quickly we can supply your item(s) for you. Whatever you need, be it electronic semiconductors, batteries, circuit breakers, motherboards, circuit sheets, or others, our team at Internet For NSN has the part(s) that you need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-417-8690 Item Description: Circuit Breaker | 5925 | 014178690 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7274-62-3 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 1 |
AAQL | Body Style | SINGLE POLE TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC SINGLE LOCATION AND 3.0 AMPERES DC SINGLE LOCATION |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
ABXD | Bushing Length | 0.175 INCHES MINIMUM |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
ADAT | Body Width | 0.700 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 SINGLE LOCATION |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE ONE |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 0.780 INCHES MAXIMUM |
AJWX | Mounting Surface To Terminal End Distance | 1.852 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.700 INCHES NOMINAL |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3600.000 MINIMUM AT 115 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote