Here at Internet of NSN, our team supplies and delivers NSN parts such as 42480 and Transformer Power from Freed Transformer Company as well as other certified producers. Our stock of items includes more than six billion new, old and out of date airline parts, along with parts for the industrial and electronics industry. One of the leading independent suppliers with a strict No China Sourcing vow, Internet of NSN has been earning its reputation as a safe and reliable parts distributor. We value our relationship with our clients which is why we have gone above and beyond in earning our ISO 9001:2015 and AS9120B certifications.
We have many NSN part numbers in our stock, including 5950002371073 and many others. If you are in a quick need to source, we are your best bet on getting that part 42480 delivered to you quickly! Simply search our parts directory for the NSN code that you need (you may also search by CAGE code or part number), and once you are able to locate the part, send in that Instant RFQ. An account manager will reach out to you in as little as fifteen minutes to provide you with a same day quote and let you know how quickly we can supply your item(s) for you. Whatever you need, be it electronic semiconductors, batteries, circuit breakers, motherboards, circuit sheets, or others, our team at Internet For NSN has the part(s) that you need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-237-1073 Item Description: Transformer Power | 5950 | 002371073 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
42480 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.120 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.245 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.255 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.875 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ADAQ | BODY LENGTH | 6.250 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 24.5 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY89.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY149.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY28.00 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY28.00 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.59 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY46.75 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND NINE SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 18876-10668614 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 37 TAB, SOLDER LUG |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |