Here at Internet of NSN, our team supplies and delivers NSN parts such as 14986 and Transformer Power from Drs Signal Solutions Inc as well as other certified producers. Our stock of items includes more than six billion new, old and out of date airline parts, along with parts for the industrial and electronics industry. One of the leading independent suppliers with a strict No China Sourcing vow, Internet of NSN has been earning its reputation as a safe and reliable parts distributor. We value our relationship with our clients which is why we have gone above and beyond in earning our ISO 9001:2015 and AS9120B certifications.
We have many NSN part numbers in our stock, including 5950004283341 and many others. If you are in a quick need to source, we are your best bet on getting that part 14986 delivered to you quickly! Simply search our parts directory for the NSN code that you need (you may also search by CAGE code or part number), and once you are able to locate the part, send in that Instant RFQ. An account manager will reach out to you in as little as fifteen minutes to provide you with a same day quote and let you know how quickly we can supply your item(s) for you. Whatever you need, be it electronic semiconductors, batteries, circuit breakers, motherboards, circuit sheets, or others, our team at Internet For NSN has the part(s) that you need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-428-3341 Item Description: Transformer Power | 5950 | 004283341 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
14986 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.500 INCHES NOMINAL3.500 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.000 INCHES NOMINAL3.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.060 INCHES NOMINAL2.060 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 45.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 450.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 104.96 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY216.24 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 104.96 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 216.24 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 18.96 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 19.74 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.27 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 66.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.01 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 18.96 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 18.56 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY19.74 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARIES,5 SECONDARIES; ALL OUTPUT CURRENTS ARE STATED AS RECTIFIED; PRIMARIES MAY BE STRAPPED FOR 230 VOLT OPERATION |
TTQY | TERMINAL TYPE AND QUANTITY | 17 WIRE LEAD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote