Here at Internet of NSN, our team supplies and delivers NSN parts such as BX-1941 and Transformer Power A from Baltimore Transformer Company as well as other certified producers. Our stock of items includes more than six billion new, old and out of date airline parts, along with parts for the industrial and electronics industry. One of the leading independent suppliers with a strict No China Sourcing vow, Internet of NSN has been earning its reputation as a safe and reliable parts distributor. We value our relationship with our clients which is why we have gone above and beyond in earning our ISO 9001:2015 and AS9120B certifications.
We have many NSN part numbers in our stock, including 5950000276417 and many others. If you are in a quick need to source, we are your best bet on getting that part BX-1941 delivered to you quickly! Simply search our parts directory for the NSN code that you need (you may also search by CAGE code or part number), and once you are able to locate the part, send in that Instant RFQ. An account manager will reach out to you in as little as fifteen minutes to provide you with a same day quote and let you know how quickly we can supply your item(s) for you. Whatever you need, be it electronic semiconductors, batteries, circuit breakers, motherboards, circuit sheets, or others, our team at Internet For NSN has the part(s) that you need.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-027-6417 Item Description: Transformer Power A | 5950 | 000276417 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bx-1941 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.172 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.202 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.985 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.560 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | AIRCRAFT, TOMCAT F-14 |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 11.55 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRMJ | WINDING POWER RATING | 300.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 1 TERMINAL BLOCK W/SCREWS |